Yes, but with modifications:
| Parts name |
Maintain tips |
Spec. |
| Pressure pump |
Check the gear oil and bearing oil every week; If there is need, fill the oil to the middle of the oil gauge; |
Gear oil model: N220; Bearing oil model: XL3H Synthetic lithium base grease |
| Oil |
For the new genset, change the oil for the first 50hours, then change every 350-500 hrs. |
15W-40, CF, advise using the oil for gas engine. |
| Desulfurizer |
Change every 6 months |
Iron ozide desulfurizer, Φ3mm |
| Oil filter |
Change together with the oil |
YX-6319 |
| Radiator water |
Change every 3months, and need to add the anti-rust water 2 bottle every time. |
Anti-rust water model: DCA 4L/bottle |
| Air filter |
Clean every 200 hours, and change every 600 hours. |
|
| Spark plug |
Clean every 200 hours, and delete the carbon sticked on the ignition electrode; change every 1000 hours. |
Special spark plug for gas engine |
| Battery |
Change every three years, and add the battery suppliment in time. |
|
| Start motor |
Clean the dust on the surface and the wires always, keep them dry; |
|
A generator set consists of the following core parts: